Article · International Journal of Geomate · March 18, 2018
GEOTECHNICAL CONSIDERATIONS OF PILING TESTING IN PROBLEMATICAL SOILS OF WEST KAZAKHSTAN
Abstract
Estimation of bearing capacity and settlement plays an essential role in designing pile foundations of buildings. This paper presents the results of pile static and dynamic loading tests taken place in the construction sites of Caspian Sea Port Prorva and Tengiz. The static loading tests (SLT) and static compression loading tests (SCLT) were carried out according to the Kazakhstan GOST and ASTM standards correspondingly. The dynamic loading tests (DLT) were performed by GOST, as well as by pile dynamic analyzer (PDA) in accordance with ASTM standards. According to the results of DLT of driven joint piles (with a cross-section of 40×40 cm, lengths of 25 m and 27 m) performed by PDA, the bearing capacity of the piles was 2143 kN. In the construction site of Prorva, the bearing capacities of driven joint piles according to the results of SCLT were2067 kN and 2042 kN. In the construction site of Tengiz, the bearing capacities of driven piles tested by SLT were 1000 kN and 1605kN. These investigations are important for the understanding of soil-structure interaction, especially of driven piles with a cross-section of 40x40 cm and lengths of 12 and 16m in construction site Tengiz.
More by Askar Zhussupbekov
- Closure to “Impact of Gradation Effects on the Particle Breakage and Mechanical Response of Calcareous Sands”International Journal of Geomechanics · 2026
- Soil Arching Developed in Foundations of Unconnected Piles Under Seismic LoadingSoil Mechanics and Foundation Engineering · 2026
- Utilization of the Piezo Drive Cone: On-Site Investigation for Liquefaction Potential AnalysisSoil Mechanics and Foundation Engineering · 2026
- A Study on the Total Factor of Safety for Liquefaction Potential AssessmentSoil Mechanics and Foundation Engineering · 2026