Article · Trudy Universiteta · June 30, 2023
Analysis of Complex Tests of the Module Piles in Difficult Soil Ground
Abdulla R. Omarov, Askar Zhussupbekov, Gulshat Tleulenova, Оразова Динара Казбековна
Abstract
The purpose of the scientific work is comparative analysis using Static compression load test (SCLT) and Dynamic load test (DLT) methods to determine of bearing capacity of pile foundations in difficult soil ground. Mega project is the construction site of Cargo offloading facilities (COF) in Atyrau region. In project used 2 consists module piles. Precast concrete module piles have 16 meter piles and 11.5 meter (9.5 m) piles with joint a total length of 25.5 m and 27.5 m, cross section 40×40 cm. The design of pile foundations was carried out in accordance with the requirements of regulatory standards. DLT testing method is also need for assessment of bearing capacity for module piles. Numerical modeling of piles was carried out in the Plaxis 2D program. The interaction of module piles with difficult of soil ground of West Kazakhstan is presented.
More by Askar Zhussupbekov
- Closure to “Impact of Gradation Effects on the Particle Breakage and Mechanical Response of Calcareous Sands”International Journal of Geomechanics · 2026
- Soil Arching Developed in Foundations of Unconnected Piles Under Seismic LoadingSoil Mechanics and Foundation Engineering · 2026
- Utilization of the Piezo Drive Cone: On-Site Investigation for Liquefaction Potential AnalysisSoil Mechanics and Foundation Engineering · 2026
- A Study on the Total Factor of Safety for Liquefaction Potential AssessmentSoil Mechanics and Foundation Engineering · 2026